dc.contributor.authorNascimento, Juber Guilherme Severino do-
dc.contributor.authorGrossi Junior, Derbal Santos-
dc.contributor.authorBarbosa, Lucas Dias Martins-
dc.date.accessioned2026-05-12T11:33:28Z-
dc.date.available2026-05-12T11:33:28Z-
dc.date.issued2024-12-10-
dc.identifier.citationProfessor orientador: Dr. José Eduardo Henriques da Silvapt_BR
dc.identifier.urihttp://hdl.handle.net/123456789/5412-
dc.descriptionA automação da rede de distribuição de energia tem se mostrado uma estratégia eficaz para melhorar a qualidade do fornecimento e reduzir o tempo de resposta em casos de interrupções. Este trabalho tem como objetivo apresentar uma análise comparativa entre o método tradicional de atendimento a uma chave fusível religadora no distrito de Cataguarino, em Cataguases, e o uso do dispositivo automatizado RD ROCKET- 1. A metodologia adotada envolveu a análise de dados operacionais fornecidos pela concessionária Energisa, considerando indicadores como Tempo Médio de Atendimento (TMA), Tempo Médio de Deslocamento (TMP), Duração Equivalente de Interrupção por Unidade Consumidora (DEC) e Frequência Equivalente de Interrupção por Unidade Consumidora (FEC). Os resultados apontam que a implantação do RD ROCKET-1 contribuiu significativamente para a redução do tempo de deslocamento e de atendimento, além de melhorar os indicadores de continuidade do serviço. Concluise que o uso do dispositivo automatizado representa uma solução eficiente para a operação da rede elétrica, promovendo maior agilidade, confiabilidade e satisfação dos consumidores.pt_BR
dc.description.abstractThe automation of the power distribution network has proven to be an effective strategy to improve the quality of supply and reduce response time in cases of interruptions. This work aims to present a comparative analysis between the traditional method of responding to a fuse switch in the district of Cataguarino, in Cataguases, and the use of the automated device RD ROCKET-1. The adopted methodology involved the analysis of operational data provided by the concessionaire Energisa, considering indicators such as Average Response Time (ART), Average Travel Time (ATT), Equivalent Duration of Interruption per Consumer Unit (DEC) and Equivalent Frequency of Interruption per Consumer Unit (FEC). The results indicate that the implementation of RD ROCKET-1 contributed significantly to the reduction of travel and response time, in addition to improving service continuity indicators. It is concluded that the use of the automated device represents an efficient solution for the operation of the power grid, promoting greater agility, reliability and consumer satisfaction.pt_BR
dc.language.isootherpt_BR
dc.subjectEficiência operacionalpt_BR
dc.subjectReligadorespt_BR
dc.subjectDistribuição de energia elétricapt_BR
dc.subjectRD ROCKET-1pt_BR
dc.titleANÁLISE E OTIMIZAÇÃO DA EFICIÊNCIA E CONFIABILIDADE DE RELIGADORES EM SISTEMAS DE DISTRIBUIÇÃO DE ENERGIA ELÉTRICA: UM ESTUDO DE CASOpt_BR