dc.descriptionO sistema elétrico da ArcelorMittal Tubarão é constituído por 2 barramentos de 138kV. Nestes barramentos são conectados 6 geradores que são impulsionados por turbinas a vapor, vapor este gerado pela queima dos gases produzidos no processo siderúrgico da própria empresa. Um dos barramentos é conectado ao Sistema Interligado Nacional (SIN) através da concessionaria local (EDP Escelsa). Entre estes barramentos de forma estratégica foram instalados disjuntores (Bustie) com proteções para que quando haja uma eventual variação no SIN, o mesmo faça a desinterligação do sistema elétrico da AMT x SIN, protegendo as barras que estão conectados os geradores e todas as cargas de relevância da usina. Este barramento é chamado de barra de geração. Para que esses disjuntores (Bustie) façam a abertura do sistema elétrico, o fluxo de potência deverá está dentro de um limite pré-definido pela capacidade dos geradores em assumir ou rejeitar tal potência. Para esse tipo de configuração se fez necessário a instalação de um sistema que possa realizar a rejeição de geração ou carga, de forma que quando o limite pré-definido seja ultrapassado, haja a adequação para uma desinterligação segura. Este sistema é denominado de SRCG, que além de rejeitar cargas e geração para controle do fluxo nos disjuntores Bustie, faz o controle de frequência em modo automático com o sistema desinterligado. A referida proposta nesse artigo faz com que o SRCG monitore a frequência da barra de geração com o sistema desinterligado, mesmo com o SRCG em manual. Com essa proposta implantada pode-se evitar algumas perdas indesejáveis no sistema elétrico da ArcelorMittal Tubarão, fazendo que o sistema elétrico fique mais confiável.pt_BR
dc.description.abstractArcelorMittal Tubarão's electrical system consists of 2 138kV busbars, 6 generators are connected to these buses, which are driven by steam turbines, steam generated by burning gases produced in the company's own steelmaking process. One of the busbars is connected to the National Interconnected System (SIN) through the local concessionaire (EDP Escelsa), between these buses, circuit breakers (Bustie) with protections were strategically installed so that when there is a possible variation in the National Interconnected System (SIN), the same do the deinterconnection of the AMT x SIN electrical system, protecting the buses that are connected to the generators and all the relevant loads of the plant, this bus is called the generation bus. So that when these circuit breakers (Bustie) open the electrical system, the power flow must be within a pre-defined limit by the capacity of the generators to assume or reject such power. For this type of configuration, it was necessary to install a system that can reject generation or load, so that when it exceeds the pre-defined limit, it is suitable for a safe disconnection. This system is called the “Charge and Generation Rejection System (SRCG)”, which, in addition to rejecting loads and generating for flow control in Bustie circuit breakers, controls the frequency in automatic mode with the system disconnected. The proposal referred to in this article makes the Charge and Generation Rejection System (SRCG) monitor the frequency of the generation bus with the system disconnected, even with the SRCG in manual. With this proposal in place, it is possible to avoid some undesirable losses in ArcelorMittal Tubarão's electrical system, making the electrical system more reliable.pt_BR
dc.description.sponsorshipLEMOS, Fábio Feu LEMOS, João Luis Guimarãespt_BR
dc.language.isootherpt_BR
dc.subjectFrequênciapt_BR
dc.subjectBarra de geraçãopt_BR
dc.subjectSistema elétrico interligado (SIN)pt_BR
dc.titleREJEIÇÃO DE CARGAS PARA CONTROLE DE FREQUÊNCIA DE BARRAMENTO CONECTADOS À GERADORESpt_BR